Model |
Potential Cause |
Verification |
Corrective Action |
A1 |
All |
Current operating conditions do not match the unit's specifications. |
Verify that the actual operating pressure and inlet/outlet flow rates match the specified performance of the unit. Contact the factory if you require sizing data for your model. |
Reduce the outlet flow requirements, increase the operating pressure, or resize the dryer by increase the orifice size and/or size of desiccant towers. |
A2 |
PHF
PCDA
PCME
PHCA |
Sealing surface of solenoid valve core deteriorated, resulting in air leakage. |
Remove and inspect solenoid valve core by unscrewing valve assembly from bottom of manifold. |
Purchase solenoid repair kit from PUREGAS and replace solenoid core and base. |
A3 |
All |
Desiccant tower contamination. |
Check inlet filtration for proper operation and inspect outlet air line for evidence of oil. |
Replace or repack desiccant towers. Replace or install proper inlet filtration. See the Maintenance Section for details. |
A4 |
PHF
PCDA
PCME
PHCA |
Desiccant tower attrition. |
Remove chamber and depress perforated disc at open end of tower. |
If perforated disc can be depressed more than 1/4" from the retaining ring, replace or repack desiccant towers. |
A5 |
All |
Solenoid coil burned out. |
Listen for a distinctive “click” when the solenoid is energized. |
Contact PUREGAS for a replacement solenoid valve assembly. |
A6 |
All |
Inlet air temperature exceeds specified maximum. |
Inlet air temperature should not exceed maximum for operating conditions (usually 70ºF or 100ºF). |
Reduce inlet air temperature or resize dryer. |
A7 |
All |
Dirty or obstructed inlet air filter element. |
Check service life indicator on top of filter (if equipped) or inspect filter element surface for coating of dirt or condensate. |
Replace filter element. |
A8 |
All |
Purge orifice plugged. |
Remove and inspect purge orifice. |
Clean hole of debris using an air gun. Do not force a wire through the critically-drilled orifice. |
A9 |
All |
Timer defective. |
Measure the output voltage from the timer, as per the cycle and voltage of your model. See Maintenance Section for more information. |
Replace timer if defective. |
A10 |
PCR |
Purge flow restricted. |
Check mufflers for excessive back-pressure. |
Replace mufflers. |