AIR 1500TM

Portable Waveguide Dehydrator

 

The AIR 1500TM was designed for small central offices, antenna lines, coaxial cables, waveguide and cellular radio systems requiring small volumes of controlled dry air. The lightweight and compact design can be easily mounted on the floor or a shelf. Unit comes standard with rubber feet for noise reduction.

  • Heatless self-reactivating desiccant twin tower drying system. Delivers air below -40°F dewpoint.
  • All gauges and controls located on the front of the unit for easy reading and adjustments.
  • Standard 50 PSIG compressor and 0-15 PSIG output range. Optional 100 PSIG compressor is available for use with air tools.
  • Solid-state timer offers longer and more reliable operation than mechanical versions.
  • Pressure switch cycles compressor on/off as load demands.
  • Optional low pressure alarm switch and other low pressure options and features are available upon request.
  • Reliable oilless compressor to assure oil-free air at all times.
  • Equipped with sealed ball bearings and Teflon rings for low friction and high reliability.


AIR 1500TM Portable Waveguide Dehydrator

Models


Part No. Description
AIR 1500TM Standard Tank Mounted Unit, 115/1/60, 1500 SCFD normal capacity - 2000 SCFD emergency capacity. Equipped with Regulator, Heatless Dryer, Moisture Indicator, and 1/2 HP Compressor with 20 Foot Power Cord.
AIR 1500TM-2 Standard Tank Mounted Unit, 220/1/50, 1500 SCFD normal capacity - 2000 SCFD emergency capacity. Equipped with Regulator, Heatless Dryer, Moisture Indicator, and 1/2 HP Compressor with 20 Foot Power Cord.


Options


Part No. Description
9871 Humidity Alarm Kit, 110 VAC. Provides a Solid State Control Circuit using a 10% Relative Humidity Sensor installed in a Humidity Tube to output a Humidity Alarm using dry contacts and a visual alarm lamp in the event of a High Humidity Output.
9872 Humidity Alarm Kit, 220 VAC. Provides a Solid State Control Circuit using a 10% Relative Humidity Sensor installed in a Humidity Tube to output a Humidity Alarm using dry contacts and a visual alarm lamp in the event of a High Humidity Output.
9873 Humidity Alarm Kit, 110 VAC. Provides a Solid State Control Circuit using a 3% Relative Humidity Sensor installed in a Humidity Tube to output a Humidity Alarm using dry contacts and a visual alarm lamp in the event of a High Humidity Output.
9874 Humidity Alarm Kit, 220 VAC. Provides a Solid State Control Circuit using a 3% Relative Humidity Sensor installed in a Humidity Tube to output a Humidity Alarm using dry contacts and a visual alarm lamp in the event of a High Humidity Output.
9875 Low-Low Pressure Regulator Assembly. Replaces the standard 0 - 15 PSIG range Outlet Regulator and Gauge with a 0.5 - 2.7 PSIG range Outlet Regulator and a 0 - 3 PSIG Outlet Regulator Gauge.
9876 Low-Low Pressure Alarm Switch Assembly. Required if Low-Low Pressure Regulator option is ordered. This will allow the Low Range Alarm to be set.


To Download files, Right-click on the link and select "Save Target As..." or "Save Link As..."




Documentation

AIR 1500TM Specification Sheet

AIR 1500TM Operating Manual

AIR 1500TM-L Operating Manual